ULTRASONIC FLOW METER IS-4000

  • Type
    IS-4000  
  • Enclosure
    Aluminum housing
  • Protection class
    IP67
Request A Quote

The IS-4000 is an intelligent and versatile ultrasonic meter/controller designed to measure level, volume and open channel flow. The meter includes a non-contact ultrasonic level sensor to detect the water level and calculates the flow rate and total volume based on characteristics of the channel.

 

General Specification
 Type 

IS-4000  

Power  92…275V AC (50/60 Hz), < 14 VA 
Dimensions HxWxD

D 148 x 164 x 60 mm

Protection class 

IP67

Display   Graphical LCD 64 × 128, backlight
Configuration  3 front-panel mounted push-buttons or mini USB with IP67 connector included
Enclosure Die cast powder-coated aluminium
Cable Connection Supply and signal cables 2 × M20
Environmental –20  to 60° C
Analog output 4…20 mA, 0…20 mA, 0…10 mA ≤ 800 Ohm, active or passive
Level sensor input 4…20 mA from level sensor
Digital outputs  2 open collectors; passive: maximum 32V DC, 0…100 Hz 100 mA, 100…10.000 Hz 20 mA; active: 24V DC, maximum 20 mA; Select
active pulse (up to 2000 msec), minimum/maximum alarm, error messages or pump control
  Solid-state relay (n.o./n.c.) maximum 230V AC, 500 mA, 1 Hz; Function is linked with open collector output 2
Digital input  5…30V DC; totalizer reset, positive return zero, BEACON/AquaCUE connectivity
Communication  RS485 Modbus RTU, Modbus TCP/IP Ethernet, BEACON/AquaCUE connectivity
Programming port Mini USB, IP67
Datalogger 2 MB capacity with 130,000 logged lines: date, level, flow rate, tank volume
Security Three-level password
Languages English, French, German, Italian, Spanish, Czech, Russian
Certification CE Low Voltage Directive 2014/35/EU, EMC 2014/30/EU, RoHS 2006 2011/65/EU, 2015/863/EU, 2017/2102/EU
Sensors Specification 
Type

Measuring range

Offset  Beam angle  Material  Approval 
DL10  50…1250 mm 50mm PVDF .CE, RoHS
DL24 

100…3000 mm

100mm  PVDF .CE, RoHS

ULM53 

200…6000 mm 200mm 14° PVC/PVDF .CE, RoHS
ULM70  150…2000 mm 150mm  10° PVC/PVDF II 1/2G Ex ia IIB T5

. Influent- and effluent measurements

. Storm and sanitary sewer systems

. Industrial discharge

. Agriculture irrigation channels