Fixed Gas Flow meter for Hazardous Area - G800

  • Flow Velocity
    0.01...35 m/s
  • Measuring Functions
    Physical Quantities: operating volumetric flow rate, standard volumetric flow rate, mass flow rate, flow velocity
  • Data Logger
    Capacity > 100 000 measured values
  • Number of flow measuring channels
    1, optional: 2
Request A Quote

The Explosion-proof Expert

The FLUXUS G800 is the ideal gas flow meter for permanent installation in potentially explosive atmospheres (ATEX (IECEx) approved for Zone 1).

With its flameproof housing (IP66) the gas flow meter is designed for industrial use in harsh environments such as in gas processing plants and natural gas extraction or the chemical and petrochemical industry.

The FLUXUS G800 gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe.

Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME) the measurement system is drift free and zero stable ensuring accurate readings. Moreover, as the transducer calibration data is automatically loaded by connecting the transducer to the transmitter, set-up times are reduced and precise, long-term stable results are provided.

Technical Data:

General Specification
flow velocity

0.01...35 m/s, depending on pipe diameter

repeatability  0.15 % of reading ±0.01 m/s
medium

all acoustically conductive gases,
e.g. nitrogen, air, oxygen, hydrogen, argon, helium, ethylene, propane

Accuracy (volumetric flow rate) 

± 1...3 % of reading ±0.01 m/s depending on application
± 0.5 % of reading ±0.01 m/s with field calibration

housing material cast aluminum 
G800, G800P, G800C24:
powder coated
G800L, G800LP, G800LC24:
special offshore coating
Transmitter degree of protection IP66
number of flow measuring
channels
1, optional: 2
display 2 x 16 characters, dot matrix, backlight
physical quantities operating volumetric flow rate, standard volumetric flow rate, mass flow rate, flow velocity
totalizer volume, mass
Data Logger capacity > 100 000 measured values
loggable values all physical quantities, totalized values and diagnostic values
power supply

For G800, G800L, G800P, G800LP: 100...240 V/50...60 Hz or 20...32 V DC or on request: 11...16 V DC

For G800C24, G800LC24: 24 V DC ±10 %

Communication Interface

For G800, G800L, G800P, G800LP: process integration (optional): RS485 (emitter) or Modbus/RS485 (emitter) or HART, diagnosis: RS2321

For G800C24, G800LC24: diagnosis: RS2321

Outputs Current, Frequency, binary

serial data kit (optional) 

software (all Windows™ versions)

FluxData: download of measurement data, graphical presentation,
conversion to other formats (e.g. for Excel™)
- FluxKoef: creating medium data sets
Explosion Protection

For Transmitter: Zone 1

For Transducer: Zone 1 

Gas processing, natural gas extraction, gas transport and storage

Chemical Industry

Petrochemical Industry