DLT 2.0 Differential Level Transmitter
- Maximum Range of Sensor
15 ft (4.57m) - Accuracy
±0.25% of Range - Output
Isolated 4-20mA, 1000 ohm load maximum - Data Logger
2 million point logger with USB output and Windows software
DLT 2.0 Differential Level Transmitter
Reduce costs and simplify instrumentation at treatment plant headworks. The DLT 2.0 can measure both differential level plus flow through a flume. Install one Sensor on each side of a mechanical bar screen to continuously monitor, transmit and control level. Use the built-in control relays or 4-20mA outputs to automatically activate the bar screen rake at present levels.
The DLT 2.0 is a simple solution for bar screen level control at wastewater treatment plants, pump stations and combined sewer systems. It includes two non-contacting ultrasonic sensors to measure level. With sensors positioned above a channel, up and downstream from the bar screen, the DLT 2.0 can display and transmit differential level. The downstream sensor can also be installed above a flume or weir to measure and totalize open channel flow.
Three 4-20mA outputs are configured to transmit upstream level, downstream level (or flow) and differential level. Built-in relays can be calibrated for level control, differential level control or open channel flow.
Other DLT 2.0 applications include two-tank inventory where you can monitor level in two tanks with one instrument. The DLT 2.0 will alternate display of level in both tanks plus transmit 4-20mA outputs. Use the built-in relays to activate alarms or level controls. This versatile dual-sensor instrument can also be configured as a submergence alarm for Par shall flumes.
General Specification | |
---|---|
Electronics Enclosure |
Watertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover |
Accuracy | ±0.25% of Range or 2 mm (0.08") whichever is greater, Repeatability and Linearity: ±0.1% |
Display |
White, backlit matrix - displays upstream, downstream and differential level, open channel flow and totalizer, relay states, operating mode and calibration menu |
Programming | built-in 5-key calibrator with English, French or Spanish language selection |
Power Input | 100-240VAC 50-60Hz |
Output | Three Isolated 4-20mA (upstream and downstream level (or open channel flow) and differential level, 1000 ohm load maximum |
Control Relays | Qty 2, rated 5 amp SPDT, programmable for level control, differential control, or flow proportional pulse |
Electrical Surge Protection | Sensor, 4-20mA and AC power input |
Operating Temp. (electronics) | -5° to 140°F (-20° to 60°C) |
Sensor Specification | |
---|---|
Maximum Range |
15 ft (4.57 m) with standard PZ15 sensor |
Deadband (Blanking) | Programmable, Minimum 8" |
Beam Angle |
8° |
Operating Frequency |
92 KHz |
Exposed Materials | PVC |
Operating Temperature | 40° to 150°F (-40° to 65°C) with automatic temperature compensation |
Operating Pressure | 20 psi (1.35 bar) maximum |
Sensor Cable | RG62AU coaxial |
Submerged Flow Alarm
Two-Tank Inventory
Barscreen Differential
Barscreen Differential plus Open Channel Flow