TCM 028K
- Mass Flow Rate (Max.):
28000 kg/h or 1029 lb/min - Volumetric Flow Rate (Max.):​
28000 l/h or 123.3 gpm or 4227 bbl/d - Standard Pressure Rating:
Up to 100 bar or 1450 psi - Nominal Meter Size:
DN25 or 1″
Robust for long life
Delivers increased productivity
Minimal pressure effects despite dynamical pressure changes
Customized installation length
Considerable cost savings for installation
Excellent repeatability
Delivers increased product quality
Optional net oil functionality
Increased well efficiency
General Specification | |
---|---|
Measuring Ranges: | |
Mass Flow Rate (max) | 28000 kg/h or 1029 lb/min |
Volumetric Flow Rate (max) | 28000 l/h or 123.3 gpm or 4227 bbl/d |
Pressure: | |
Standard Pressure Rating | Up to 100 bar |
Accuracy (Liquids): | |
Basic Accuracy (Mass Flow) | ±0.1 % of flow rate |
Mass Flow Repeatability | ±0.05 % of flow rate |
Basic Accuracy (Volume Flow) | ±0.15 % of flow rate |
Volume Flow Repeatability | ±0.05 % of flow rate |
Zero Stability | ±0.01 % of full scale |
Accuracy (Gases): | |
Basic Accuracy (Mass Flow) | ±0.5 % of flow rate |
Mass Flow Repeatability | ±0.25 % of flow rate |
Accuracy ±0.10 % of flow rate + zero stability (%) x (max. flow rate/current flow rate) Stated flow accuracy combines the effects of repeatability, linearity and hysteresis |
|
Density: | |
Density Range | up to 2500 kg/m³, 2.5 g/cm³ |
Density Accuracy | Liquids ±1.0 kg/m³, ±0.001 g/cm³ |
Density Repeatability | ±0.5 kg/m³, ±0.0005 g/cm³ |
Temperature: | |
Process Temperature Range | Standard: -40 °C…+100 °C, -40 °F …+212 °F / Optional -60 °C…+200 °C, -76 °F…+392 °F |
Temperature Accuracy | ±1 °C, 1.8 °F ±0.5 % of reading |
Temperature Repeatability | ±0.2 °C, ±0.36 °F |
Material: | |
---|---|
Tubes | 1.4404/AISI 316L |
Case | 1.4301/AISI 304 (1.4404/316L) |
Flow splitter | CF3M/AISI 316L |
EX Certifications: | |
ABS | Yes |
ATEX | Zone 1: Group, IIC, T4 / Zone 2: II 3G Ex nA IIC, T4 Gc |
IECEx | Zone 1: Group IIC, T4 |
cCSAus | Class I, Division 1: Group A, B, C, D, T4 |
GOST | Yes |
tcm_28k_pressure_drop.png |
new_accuracy_spec_en_150629_20_6_.jpg |
tcm_028k_marine_en_150727_e004.pdf |
tcm_e68_classic_d_en_180729_e015.pdf |