TCM 230K

  • Mass Flow Rate (Max.):
    230000 kg/h  or 8450 lb/min
  • Volumetric Flow Rate (Max.):​
    230000 l/h or 1013 gpm  or 34,720 bbl/d
  • Standard Pressure Rating:
    Up to 100 bar  or 1450 psi
  • Nominal Meter Size:
    DN80  or 3″
Request A Quote

Robust for long life

Delivers increased productivity

Minimal pressure effects despite dynamical pressure changes

Customized installation length

Considerable cost savings for installation

Excellent repeatability

Delivers increased product quality

Optional net oil functionality

Increased well efficiency

General Specification
Measuring Ranges:
Mass Flow Rate (max) 230000 kg/h  or 8450 lb/min
Volumetric Flow Rate (max) 230000 l/h or 1013 gpm  or 34,720 bbl/d
Pressure:
Standard Pressure Rating Up to 100 bar
Accuracy (Liquids):
Basic Accuracy (Mass Flow) ±0.1 % of flow rate
Mass Flow Repeatability ±0.05 % of flow rate
Basic Accuracy (Volume Flow) ±0.15 % of flow rate
Volume Flow Repeatability ±0.05 % of flow rate
Zero Stability ±0.01 % of full scale
Accuracy (Gases):
Basic Accuracy (Mass Flow) ±0.5 % of flow rate
Mass Flow Repeatability ±0.25 % of flow rate
 

Accuracy ±0.10 % of flow rate + zero stability (%) x (max. flow rate/current flow rate)

Stated flow accuracy combines the effects of repeatability, linearity and hysteresis

Density:
Density Range up to 2500 kg/m³, 2.5 g/cm³
Density Accuracy Liquids ±1.0 kg/m³, ±0.001 g/cm³
Density Repeatability ±0.5 kg/m³, ±0.0005 g/cm³
Temperature:
Process Temperature Range Standard: -40 °C…+100 °C, -40 °F …+212 °F / Optional  -60 °C…+200 °C, -76 °F…+392 °F
Temperature Accuracy ±1 °C, 1.8 °F ±0.5 % of reading
Temperature Repeatability ±0.2 °C, ±0.36 °F
Material:
Tubes 1.4404/AISI 316L
Case 1.4301/AISI 304 (1.4404/316L)
Flow splitter CF3M/1.4409/AISI 316L
EX Certifications:
ABS Yes
ATEX Zone 1: Group, IIC, T4 / Zone 2: II 3G Ex nA IIC, T4 Gc
IECEx Zone 1: Group IIC, T4
cCSAus Class I, Division 1: Group A, B, C, D, T4
GOST Yes