MF30 Range-Flow Meters
Medium Flow Positive Displacement Meter
- 0 – 180 L/Hr
- High Pressure Capability
- Accuracy: ± 1.0%
- Range of material options
The MF (or Medium Flow) VFF covers flow rates up to 180 l/hr. It was first provided in 1992. The MF30 was originally rated to 3.0 l/min – hence MF30.
General Specifications: | |
---|---|
MF30 |
0 - 180 l/hr |
Accuracy | ±1% of reading, requires linearisation. Provided by all Litre Meter instrumentation. |
Pressure Rating | Dependent on Connection size and rating. |
Temperature rating | -40°C - +100°C dependent on material and instrument; higher temperature possible. |
Viscosity Range | 0.5 - 100,000 cP or greater. |
Recommended Filtration | A 100 micron filter is advisable for 100% long life serviceability. |
Key Features: | ||
---|---|---|
Compact |
Single Moving Part |
|
No straight lengths | Large Viscosity range, from methanol upwards | |
Very Low Flow Measurement | Measures pulsing flow accurately | |
Tolerant of particulate up to 100+ microns | Preserves Molecular Integrity of fluid | |
Low pressure drop (<0.1 bar typical) | Proven since 1986 | |
Pressure independent measurement | Ultra High Pressure Capability (60,000psi, 4000bar if required) | |
Low Maintenance | Highly Durable |
Chemical Injection
Hydraulics
Wax Dispersant
Corrosion Inhbitor
Subsea Control fluid
PIB
Scale Inhibitor
Subsea flow
Ashalphtene Dispersant