Insertion Style Flow Sensors - 220 Series

  • Pipe Size
    1/2" to 4"
  • Flow Range 
    0.3...30 ft/sec
  • Temperature 
    from 0 to 105 °C
  • Pressure
    Up to 400 PSI
Request A Quote

The 220 Series sensors are specifically designed for installation in underground vaults that might be subjected to flooding. As the liquid flow turns the impeller, a low impedance 8V DC square wave signal is transmitted with a frequency proportional to the flow rate. This signal can travel up to 2,000 feet between the sensor and the display unit without the need for amplification.

General Specification
Temperature ratings


Standard Version: 221 °Fcontinuous service
High Temperature Version: 285 °F continuous service; 305 °F peak temperature (limited duration)

Pressure ratings for 220BR


At 100° F: 400 PSI
At 300° F (High Temperature Version Only): 325 psi

Pressure ratings for 220SS

- At 100F  400psi

- At 300F  325psi

Pipe size range 3” up to 40”
Recommended design flow range

0.5…30 ft/sec Initial detection below 0.3 ft/sec

Accuracy ± 1.0% of full scale over recommended design flow range
Repeatability
±0.3% of full scale over recommended design flow range 
Linearity
±0.2% of full scale over recommended design flow range
Output frequency 3.2 Hz to 200 Hz
Output pulse width
 
5 msec ±25%
 
Electrical cable for standard sensor electronics 20 ft (6 m) of 2-conductor 20 AWG shielded UL type PTLC wire provided for connection to display or analog transmitter unit. Rated to 221° F (105° C). May be extended to a maximum of 2000 ft (610 m) with similar cable and insulation appropriate for application.
 
Electrical cable for IR sensor electronics 48 in. (122 cm) of UL style 116666 copper solid AWG 18 wire with direct burial insulation. Rated to 221° F (105° C).

-Building Design, HVAC & Plumbing
-Utility Water Treatment & Distribution
-Process & General Industry